Table 12.1 Limitations on roof coverings

Department for Communities and Local Government, (2019) Table 12.1 Limitations on roof coverings. [Image]

[img]
Preview
Image
b-volume-1-table-12-1-limitations-on-roof-coverings.jpg

Download (431kB) | Preview
[img] Image
b-volume-1-table-12-1-limitations-on-roof-coverings.svg

Download (61kB)
[img] Text
b-volume-1-table-12-1-limitations-on-roof-coverings.docx
Restricted to Repository staff only

Download (11kB)

Abstract

NOTES:
Separation distances do not apply to the boundary between roofs of a pair of semi-detached dwellinghouses and to enclosed/covered walkways. However, see Diagram 5.2 if the roof passes over the top of a compartment wall.
Polycarbonate and uPVC rooflights that achieve a class C-s3, d2 rating by test may be regarded as having a BROOF(t4) designation.
1. The designation of external roof surfaces is explained in Appendix B.
2. Not acceptable on any of the following buildings.
a. Dwellinghouses in terraces of three or more dwellinghouses.
b. Any other buildings with a cubic capacity of more than 1500m3.
3. Acceptable on buildings not listed in (1) if both of the following apply.
a. Part of the roof has a maximum area of 3m2 and is a minimum of 1500mm from any similar part.
b. The roof between the parts is covered with a material rated class A2-s3, d2 or better.

Item Type: Image
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: dwellinghouse, rooflight, roof, boundary, boundary, capacity, unprotected area
Subjects: Section 12: Resisting fire spread over roof coverings
B4: External fire spread
Building standards