Basements

Department for Communities and Local Government, (2019) Basements. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 3: Means of escape – flats, 1 (3.9). RIBA Publishing Publication, London, p. 20. ISBN 9781859469156

Full text not available from this repository.

Abstract

Basement storeys containing habitable rooms should have one of the following.
a. An emergency escape window or external door providing escape from the basement (see paragraph 3.6).
b. A protected stairway (minimum REI 30) leading from the basement to a final exit.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: basement storey, basement, storey exit, escape route, protected stairway, habitable room, escape lighting, exit passageway, habitable room, circulation space
Subjects: T Technology > TH Building construction > Building standards > fire safety - volume 1: dwellings. 2019 edition - for use in england > Section 3: Means of escape – flats