Additional guidance

Department for Communities and Local Government, (2019) Additional guidance. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 6: Loadbearing elements of structures – flats, 1 (6.3). RIBA Publishing Publication, London, p. 57. ISBN 9781859469156

Full text not available from this repository.

Abstract

If a loadbearing wall is any of the following, guidance in other sections may also apply.
a. A compartment wall (including a wall common to two buildings): Section 7.
b. Enclosing a place of special fire hazard: Section 7.
c. Protecting a means of escape: Sections 2 and 3.
d. An external wall: Sections 10 and 11.
e. Enclosing a firefighting shaft: Section 15.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: firefighting shaft, section, fire-separating element, element of structure, definitions (ada), compartment wall, external wall, unprotected area, pier, firefighting lift
Subjects: T Technology > TH Building construction > Building standards > fire safety - volume 1: dwellings. 2019 edition - for use in england > Section 6: Loadbearing elements of structures – flats
K Law > The Building Regulations 2010 > B1: Means of warning and escape
T Technology > TH Building construction > Building standards
Date Deposited: 15 Feb 2020 06:02
Last Modified: 13 Oct 2021 19:40
URI: https://buildvoc.co.uk/id/eprint/517