Items where Year is Not Specified

Up a level
Export as [feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
Jump to: D
Number of items: 7.

D

ADB1 UNSPECIFIED Para:UNSPECIFIED Diagram D1 Measurement of door width

Effective clear width (door stop to projecting ironmongery)
Effective clear width (door stop to door leaf)

UNSPECIFIED

ADB1 UNSPECIFIED Para:UNSPECIFIED Table D1 Floor space factors

NOTES:
1. As an alternative to using the values in the table, the floor space factor may be determined by reference to actual data taken from similar premises. Where appropriate, the data should reflect the average occupant density at a peak trading time of year.
2. Where accommodation is not directly covered by the descriptions given, a reasonable value based on a similar use may be selected.
3. Where any part of the building is to be used for more than one type of accommodation, the most onerous factor(s) should be applied. Where the building contains different types of accommodation, the occupancy of each different area should be calculated using the relevant space factor.
4. For detailed guidance on appropriate floor space factors for concourses in sports grounds refer to Concourses published by the Football Licensing Authority.
5. Alternatively the occupant number may be taken as the number of fixed seats provided, if the occupants will normally be seated.
6. Shops excluding those under item 10, but including: supermarkets and department stores (main sales areas), shops for personal services, such as hairdressing, and shops for the delivery or collection of goods for cleaning, repair or other treatment or for members of the public themselves carrying out such cleaning, repair or other treatment.
7. Shops (excluding those in covered shopping complexes but including department stores) trading predominantly in furniture, floor coverings, cycles, prams, large domestic appliances or other bulky goods, or trading on a wholesale self-selection basis (cash and carry).

UNSPECIFIED

ADB1 UNSPECIFIED Para:UNSPECIFIED Diagram D3 Area

a. Surface area: roofs and rooflights In each case measure the visible area
b. Floor area: Room, garage, conservatory or outbuilding, measure to inner surface of enclosing walls
c. Floor area: Storey, part or compartment, measure to inner surface of enclosing walls and include internal walls and partitions

UNSPECIFIED

ADB1 UNSPECIFIED Para:UNSPECIFIED Diagram D4 Height of building

Height of building

UNSPECIFIED

ADB1 UNSPECIFIED Para:UNSPECIFIED Diagram D5 Number of storeys

NOTES:
1.In assembly buildings (purpose group 5), a gallery is included as a storey, but not if it is a loading gallery, fly gallery, stage grid, lighting bridge, or any gallery provided for similar purposes, or for maintenance and repair.
2.In other purpose group buildings, galleries are not counted as a storey.
3.For the definition of basement, see Appendix A.

UNSPECIFIED

ADB1 UNSPECIFIED Para:UNSPECIFIED Diagram D6 Height of top storey in building

Height of top storey measured from upper floor surface of top floor to ground level on lowest side of building
Height of top storey excludes roof-top plant areas and any top storeys consisting exclusively of plant rooms

UNSPECIFIED

ADB1 UNSPECIFIED Para:UNSPECIFIED Diagram D7 Free area of smoke ventilators

Free area measured at right angles to air flow
Free area for louvred vent = a1+a2+a3+a4+a5

UNSPECIFIED

This list was generated on Mon Dec 30 17:00:58 2024 UTC.