Department for Communities and Local Government, (2019) Fire doorsets C6. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Appendix C: Fire doorsets, 1 (C6). RIBA Publishing Publication, London, 135 - 135. ISBN 9781859469156
Full text not available from this repository.Abstract
If a self-closing device would be considered to interfere with the normal approved use of the
building, self-closing fire doors may be held open by one of the following.
a. A fusible link, but not if the doorset is in an opening provided as a means of escape unless it
complies with paragraph C7.
b. An automatic release mechanism activated by an automatic fire detection and alarm system.
c. A door closer delay device.