Fire doorsets C8

Department for Communities and Local Government, (2019) Fire doorsets C8. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Appendix C: Fire doorsets, 1 (C8). RIBA Publishing Publication, London, 135 - 135. ISBN 9781859469156

Full text not available from this repository.

Abstract

Fire doorsets often do not provide any significant insulation. Unless providing both integrity
and insulation in accordance with Appendix B, Table B3, a maximum of 25% of the length of a
compartment wall should consist of door openings.
Where it is practicable to maintain a clear space on both sides of the doorway, the above
percentage may be greater.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: fire doorset, doorset, compartment wall, should
Subjects: Appendix C: Fire doorsets