Internal linings

Department for Communities and Local Government, (2002) Internal linings. In: Approved Document B: Fire Safety - Volume 2: Buildings other than dwellinghouses. 2002 ed. Appendix A: Performance of materials and structures, 2 (13). RIBA Publishing Publication, London, p. 114. ISBN 1859462014

Full text not available from this repository.

Abstract

The highest national product performance classification for lining materials is Class 0. This is achieved if a material or the surface of a composite product is either:
a. composed throughout of materials of limited combustibility; or
b. a Class 1 material which has a fire propagation index (I) of not more than 12 and sub-index (i1) of not more than 6.
Note: Class O is not a classification identified in any British Standard test.