Department for Communities and Local Government, (2022) Internal planning of multi-storey flats. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2022 ed. Section 3: Means of escape – flats, 1 (3.21). RIBA Publishing Publication, London, p. 23. ISBN 9781859469156
This is the latest version of this item.
Abstract
When multi-storey flats do not have their own external entrance at ground level, adopt one of the following approaches.
a. Approach 1 – provide at least one alternative exit from each habitable room that is not on the entrance storey of the flat (Diagram 3.5 and paragraph 3.22).
b. Approach 2 – provide at least one alternative exit from each storey that is not the entrance storey of the flat. All habitable rooms should have direct access to a protected landing (Diagram 3.6 and paragraph 3.22).
Approach 3 – provide a protected stairway plus a sprinkler system in accordance with Appendix E (smoke alarms should also be provided in accordance with Section 1).
d. Approach 4 – if the vertical distance between the entrance storey of the flat and any of the storeys above or below does not exceed 7.5m, provide all of the following.
i. A protected stairway.
ii. Additional smoke alarms in all habitable rooms.
iii. A heat alarm in any kitchen.
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | alternative exit, habitable room, protected stairway, entrance storey, storey exit, access room, habitable room, storey, high-usage entrance door |
Subjects: | Section 03: Means of escape – flats |
Depositing User: | admin |
Date Deposited: | 25 Jun 2022 05:08 |
Last Modified: | 21 Dec 2022 09:07 |
URI: | https://buildvoc.co.uk/id/eprint/1640 |
Available Versions of this Item
-
Internal planning of multi-storey flats. (deposited 01 Feb 2020 08:10)
- Internal planning of multi-storey flats. (deposited 25 Jun 2022 05:08) [Currently Displayed]