Department for Communities and Local Government, (2022) External escape stairs. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2022 ed. Section 3: Means of escape – flats, 1 (3.66). RIBA Publishing Publication, London, p. 34. ISBN 9781859469156
This is the latest version of this item.
Official URL: https://www.gov.uk/government/publications/approve...
Abstract
Where a storey (or part of a building) is served by a single access stair, that stair may be external provided both of the following conditions are met.
a. The stair serves a floor not more than 6m above the ground level.
b. The stair meets the provisions in paragraph 3.68.