Department for Communities and Local Government, (2022) Materials and products. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2022 ed. Section 10: Resisting fire spread over external walls, 1 (10.6). RIBA Publishing Publication, London, p. 80. ISBN 9781859469156
This is the latest version of this item.
Abstract
In a building with a storey 18m or more in height (see Diagram D6 in Appendix D) any insulation product, filler material (such as the core materials of metal composite panels, sandwich panels and window spandrel panels but not including gaskets, sealants and similar) etc. used in the construction of an external wall should be class A2-s3, d2 or better (see Appendix B). This restriction does not apply to masonry cavity wall construction which complies with Diagram 8.2 in Section 8. Where regulation 7(2) applies, that regulation prevails over all the provisions in this paragraph.
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | diagram d4 height of building, height, unprotected area, measurement |
Subjects: | Section 10: Resisting fire spread over external walls |
Depositing User: | admin |
Date Deposited: | 03 Jul 2022 06:21 |
Last Modified: | 14 Jul 2022 17:22 |
URI: | https://buildvoc.co.uk/id/eprint/1663 |
Available Versions of this Item
-
Materials and products. (deposited 15 Feb 2020 05:26)
- Materials and products. (deposited 03 Jul 2022 06:21) [Currently Displayed]