Combustibility of external walls

Department for Communities and Local Government, (2022) Combustibility of external walls. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2022 ed. Section 10: Resisting fire spread over external walls, 1 (10.3). RIBA Publishing Publication, London, p. 79. ISBN 9781859469156

This is the latest version of this item.

Full text not available from this repository.

Abstract

The external walls of buildings other than those described in regulation 7(4) of the Building Regulations should achieve either of the following.
a. Follow the provisions given in paragraphs 10.5 to 10.9, which provide guidance on all of the following.
i. External surfaces.
ii. Materials and products.
iii. Cavities and cavity barriers..
b. Meet the performance criteria given in BRE report BR 135 for external walls using full-scale test data from BS 8414-1 or BS 8414-2.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: cavity barrier, external wall, wall
Subjects: Section 10: Resisting fire spread over external walls
B4: External fire spread
Building standards
Depositing User: admin
Date Deposited: 11 Jul 2022 19:44
Last Modified: 11 Jul 2022 19:44