Department for Communities and Local Government, (2019) Sheltered housing. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 0: Approved Document B: Fire safety - dwellings, 1 (0.11). RIBA Publishing Publication, London, p. 3. ISBN 9781859469156
Full text not available from this repository.Abstract
While many of the provisions in this approved document for means of escape from flats are applicable to sheltered housing, the nature of the occupancy may necessitate some additional fire protection measures. The extent of such measures will depend on the form of the development. For example, a group of specially adapted bungalows or two storey flats, with few communal facilities, will not need to be treated differently from other single storey or two storey dwellinghouses or flats.
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | sheltered housing, single storey, documents (housing), means of escape, measurement, fire protection, dwellinghouse, flat, principal communal entrance |
Subjects: | Building standards |
Date Deposited: | 29 Dec 2019 07:22 |
Last Modified: | 29 Sep 2022 21:03 |
URI: | https://buildvoc.co.uk/id/eprint/18 |