Department for Communities and Local Government, (2019) Escape from upper storeys a maximum of 4.5m above ground level. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 3: Means of escape – flats, 1 (3.16). RIBA Publishing Publication, London, p. 21. ISBN 9781859469156
Full text not available from this repository.
Official URL: https://www.gov.uk/government/publications/fire-sa...
Abstract
All habitable rooms (excluding kitchens) should have either of the following.
a. An emergency escape window or external door, as described in paragraph 3.6.
b. In multi-storey flats, direct access to a protected internal stairway (minimum REI 30) leading to an exit from the flat.
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | habitable room, habitable room, kitchen, should, window |
Subjects: | Section 03: Means of escape – flats Building standards |
Date Deposited: | 01 Feb 2020 08:11 |