Common escape routes

Department for Communities and Local Government, (2019) Common escape routes. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 3: Means of escape – flats, 1 (3.35). RIBA Publishing Publication, London, p. 30. ISBN 9781859469156

Full text not available from this repository.

Abstract

Divide a common corridor connecting two or more storey exits with a fire doorset fitted with a self-closing device (minimum E 30 Sa). See Diagram 3.8. Associated screens should be fire resisting. Site doors so that smoke does not affect access to more than one stair.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: self-closing device, fire doorset, common stair, common stair, storey exit, alternative exit, fire resistance, common parts, common balcony, protected stairway
Subjects: T Technology > TH Building construction > Building standards > fire safety - volume 1: dwellings. 2019 edition - for use in england > Section 3: Means of escape – flats
K Law > The Building Regulations 2010 > B1: Means of warning and escape
T Technology > TH Building construction > Building standards