Common escape routes

Department for Communities and Local Government, (2019) Common escape routes. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 3: Means of escape – flats, 1 (3.36). RIBA Publishing Publication, London, p. 30. ISBN 9781859469156

Full text not available from this repository.

Abstract

A fire doorset (minimum E 30 Sa) fitted with a self-closing device (and fire resisting screen, where required) should separate the dead-end portion of a common corridor from the rest of the corridor (Diagrams 3.7a, 3.8b and 3.8c).

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: self-closing device, fire doorset, doorset, should, fire resistance, fire resisting (Fire resistance), floating layer
Subjects: Section 03: Means of escape – flats