Department for Communities and Local Government, (2019) Amount of opening and effect on associated escape routes. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 3: Means of escape – flats, 1 (3.95). RIBA Publishing Publication, Place of Publication:, p. 39. ISBN 9781859469156
Full text not available from this repository.Abstract
All doors on escape routes should be hung to meet both of the following conditions.
a. Open by a minimum of 90 degrees.
b. Open with a swing that complies with both of the following.
i. Is clear of any change of floor level, other than a threshold or single step on the line of the doorway.
ii. Does not reduce the effective width of any escape route across a landing.