Department for Communities and Local Government, (2019) Walls. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 4: Wall and ceiling linings, 1 (4.4). RIBA Publishing Publication, London, p. 43. ISBN 9781859469156
Full text not available from this repository.
Official URL: https://www.gov.uk/government/publications/fire-sa...
Abstract
Parts of walls in rooms may be of lower performance than stated in Table 4.1, but no worse than class D-s3, d2. In any one room, the total area of lower performance wall lining should be less than an area equivalent to half of the room’s floor area, up to a maximum of 20m2 of wall lining.