Compartmentation Provision of compartmentation

Department for Communities and Local Government, (2019) Compartmentation Provision of compartmentation. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 5: Internal fire spread – dwellinghouses, 1 (5.7). RIBA Publishing Publication, London, p. 51. ISBN 9781859469156

Full text not available from this repository.

Abstract

Where a door is provided between a dwellinghouse and the garage (see Diagram 5.1), it should meet one of the following conditions.
a. The garage floor should be laid such that it falls away from the door to the outside, to allow fuel spills to flow away.
b. The door opening should be a minimum of 100mm above the level of the garage floor.