Junction of compartment wall with roof

Department for Communities and Local Government, (2019) Junction of compartment wall with roof. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 5: Internal fire spread – dwellinghouses, 1 (5.13). RIBA Publishing Publication, London, p. 52. ISBN 9781859469156

Full text not available from this repository.

Abstract

Materials achieving class B-s3, d2 or worse used as a substrate to the roof covering and any timber tiling battens, fully bedded in mortar or other suitable material for the width of the wall (Diagram 5.2b), may extend over the compartment wall in buildings that are a maximum of 15m high.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: compartment wall, suitable, wall, roof, bs 8895-2:2015 material, unprotected area, materials
Subjects: Section 05: Internal fire spread – dwellinghouses