Junction of compartment wall with roof

Department for Communities and Local Government, (2019) Junction of compartment wall with roof. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 5: Internal fire spread – dwellinghouses, 1 (5.14). RIBA Publishing Publication, London, p. 52. ISBN 9781859469156

Full text not available from this repository.

Abstract

Double-skinned insulated roof sheeting should incorporate a band of material rated class A2-s3, d2 or better, a minimum of 300mm in width, centred over the wall.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: wall, should, materials, roof, bs 8895-2:2015 material, unprotected area
Subjects: Section 05: Internal fire spread – dwellinghouses
B3: Internal fire spread (structure)