Department for Communities and Local Government, (2019) Construction of compartment walls and compartment floors General provisions. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 7: Compartmentation/sprinklers – flats, 1 (7.5). RIBA Publishing Publication, London, p. 59. ISBN 9781859469156
Full text not available from this repository.
Official URL: https://www.gov.uk/government/publications/fire-sa...
Abstract
All compartment walls and compartment floors should achieve both of the following.
a. Form a complete barrier to fire between the compartments they separate.
b. Have the appropriate fire resistance, as given in Appendix B, Tables B3 and B4.
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | compartment wall or floor, compartment wall or floor, fire compartment, compartment wall |
Subjects: | Section 07: Compartmentation/sprinklers – flats B3: Internal fire spread (structure) Building standards |