Construction of compartment walls and compartment floors General provisions

Department for Communities and Local Government, (2019) Construction of compartment walls and compartment floors General provisions. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 7: Compartmentation/sprinklers – flats, 1 (7.6). RIBA Publishing Publication, London, p. 59. ISBN 9781859469156

Full text not available from this repository.

Abstract

Timber beams, joists, purlins and rafters may be built into or carried through a masonry or concrete compartment wall if the openings for them are both of the following.
a. As small as practicable.
b. Fire-stopped.
If trussed rafters bridge the wall, failure of the truss due to a fire in one compartment should not cause failure of the truss in another compartment.