Department for Communities and Local Government, (2019) Flues, etc. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 9: Protection of openings and fire‑stopping, 1 (9.23). RIBA Publishing Publication, London, p. 74. ISBN 9781859469156
Full text not available from this repository.
Official URL: https://www.gov.uk/government/publications/fire-sa...
Abstract
The wall of a flue, duct containing flues or appliance ventilation duct(s) should have a fire resistance (REI) that is at least half of any compartment wall or compartment floor it passes through or is built into (Diagram 9.5).
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | appliance ventilation duct, appliance compartment, compartment wall or floor, compartment wall or floor, fire compartment, fire wall, wall, should, fire resisting (Fire resistance), compartment (fire) |
Subjects: | Section 09: Protection of openings and fire‑stopping B3: Internal fire spread (structure) Building standards |