Department for Communities and Local Government, (2019) Additional considerations. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 10: Resisting fire spread over external walls, 1 (10.15). RIBA Publishing Publication, London, p. 82. ISBN 9781859469156
There is a more recent version of this item available. |
Abstract
Particular attention is drawn to the following points.
a. Membranes used as part of the external wall construction above ground level should achieve a minimum of class B-s3, d0.
b. Internal linings should comply with the guidance provided in Section 4.
c. Any part of a roof should achieve the minimum performance as detailed in Section 12.
d. As per regulation 7(3), window frames and glass (including laminated glass) are exempted from regulation 7(2). Window spandrel panels and infill panels must comply with regulation 7(2).
e. Thermal breaks are small elements used as part of the external wall construction to restrict thermal bridging. There is no minimum performance for these materials. However, they should not span two compartments and should be limited in size to the minimum required to restrict the thermal bridging (the principal insulation layer is not to be regarded as a thermal break).
f. Regulation 7(2) only applies to specified attachments. Shop front signs and similar attachments are not covered by the requirements of regulation 7(2), although attention is drawn to paragraph 10.15g.
g. While regulation 7(2) applies to materials which become part of an external wall or specified attachment, consideration should be given to other attachments to the wall which could impact on the risk of fire spread over the wall.
Item Type: | Book Section |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | specified attachment, thermal element, span, external wall, unprotected area, plans certificates, b4 external fire spread, should, principal works, regulation 7 - materials and workmanship |
Subjects: | Section 10: Resisting fire spread over external walls B4: External fire spread Building standards |
Date Deposited: | 15 Feb 2020 05:24 |
Last Modified: | 13 Oct 2021 19:40 |
URI: | https://buildvoc.co.uk/id/eprint/698 |
Available Versions of this Item
- Additional considerations. (deposited 15 Feb 2020 05:24) [Currently Displayed]