Department for Communities and Local Government, (2019) Table 4.2 Limitations applied to thermoplastic rooflights and lighting diffusers in suspended ceilings and class D-s3, d2 plastic rooflights(1). [Image]
Preview |
b-volume-1-table-4-2-limitations-applied-to-thermoplastic-rooflights-and-lighting-diffusers-in-suspended-ceilings-and-class-d-s3-d2-plastic-rooflights.jpg
Download (468kB) | Preview
b-volume-1-table-4-2-limitations-applied-to-thermoplastic-rooflights-and-lighting-diffusers-in-suspended-ceilings-and-class-d-s3-d2-plastic-rooflights.svg
Download (45kB)
b-volume-1-table-4-2-limitations-applied-to-thermoplastic-rooflights-and-lighting-diffusers-in-suspended-ceilings-and-class-d-s3-d2-plastic-rooflights.docx
Restricted to Repository staff only
Download (10kB)
Abstract
NOTES:
1. This table does not apply to products that meet the provisions in Table 4.1.
2. Smaller rooflights and diffusers can be grouped together provided that both of the following satisfy the dimensions in Diagram 4.2 or 4.3.
a. The overall size of the group.
b. The space between one group and any others.
3. Lighting diffusers of TP(a) flexible rating should be used only in panels of a maximum of 5m2 each. See paragraph 4.17.
4. There are no limits on the use of class D-s3, d2 materials in small rooms. See Table 4.1.
5. The minimum 3m separation given in Diagram 4.2 between each 5m2 group must be maintained. Therefore, in some cases, it may not be possible to use the maximum percentage quoted.
Item Type: | Image |
---|---|
Additional Information: | mml-maui-text-analytics-keywords |
Uncontrolled Keywords: | rooflight |
Subjects: | B2: Internal fire spread (linings) Section 04: Wall and ceiling linings Building standards |